The coating thickness gauge can nondestructive measure the thickness of non-conductive coatings on metal surfaces and non-ferromagnetic metal coatings on ferromagnetic metals (e.g. iron, nickel, cobalt, etc.), including measuring the thickness of iron, stainless steel surface paint or galvanized layer, measuring the thickness of aluminum,copper surface paint or plastic film.
EC-470 has a built-in integrated probe of magnetic induction and eddy current, with a measurement range of 0~2000μm and a measurement accuracy of ±(3%+1μm), and the resolution is up to 0.1μm.
EC-470 has a streamlined display interface with an automatic rotating screen function, which can display the average, minimum and maximum values at the same time. When measuring, the users only needs to quickly fit the probe tip to the surface of the object to be measured. During the process of the probe shrinking to the inside of the instrument, it can automatically distinguish the properties of the substrate and measure the thickness of the coating (plating) layer.
| Model | EC-470 |
|---|---|
| Probe type | Internal probe |
| Measuring principle | Fe:Magnetic induction;NFe:Eddy currents |
| Measuring range | 0~2000μm |
| Accuracy | ±(3%+1μm) |
| Resolution | 0.1μm(0~100μm);1μm(>100μm) |
| Unit | μm, mm, mil |
| Iron galvanized base material identification | 3~500μm |
| Calibration | Zero calibration |
| Statistic | Number of readings, Max, Min,Mean |
| Probe trigger force | 0.3~0.8N |
| Minimum curvature radius | Convex 5mm;Concave 25mm |
| Minimum measuring area | Diameter 15mm |
| Minimum thickness of substrate | Fe:0.30mm;NFe:0.05mm |
| Maximum measuring rate | 2 readings/s |
| Display | Dot matrix display |
| Operation environment | Temperature:-10~50℃;Humidity:20~90%RH (Non-condensing) |
| Storage environment | Temperature:-20~60℃;Humidity:20~90%RH (Non-condensing) |
| Power supply | 2 pcs 1.5V AAA alkaline batteries 2 pcs 1.2V AAA rechargeable batteries |
| Protection class | IP40 |
| Size | 102*53.6*25mm |
| Weight | About 80g (No battery) |